If the Ethernet link on your board will not come up, drops at random, or settles at 100 Mbps on a Gigabit design, the cause usually sits in the few centimetres between the PHY's MDI pins and the RJ45 jack. That stretch holds the PHY, a termination and center-tap network, the magnetics (an isolation transformer with a common-mode choke) and the connector, with protection and grounding around them. Knowing what each part does lets you read PHY registers as evidence instead of guessing. Drafted with AI assistance; facts checked against the cited datasheets and standards.

What sits between the PHY and the cable

Part Job Typical mistake
PHY Drives and receives differential signals on its MDI pins Termination that does not match its drive type
Termination and center taps Bias and decouple the PHY-side windings Voltage-mode and current-mode schemes mixed up
Magnetics (often labelled TD on schematics) 1:1 galvanic isolation plus common-mode rejection Two-channel part on a Gigabit port
RJ45 Four contact pairs for the four twisted pairs Pair order swapped between jack and transformer

Why the PHY type decides the wiring

Ethernet PHYs drive the line in one of two ways. A voltage-mode PHY terminates on-die, so its MDI lines run straight to the transformer and each PHY-side center tap is decoupled to ground with a capacitor, typically 100 nF. A current-mode PHY needs an external 49.9 Ω resistor from each MDI line to a bias supply, and the center taps are tied to that supply too.

The two schemes are not interchangeable. Reusing a reference schematic from a different PHY family is an easy way to end up with a weak link or none at all, so check the datasheet of the exact PHY you placed.

Two pairs or four

10BASE-T and 100BASE-TX use only pairs 1/2 and 3/6. 1000BASE-T (IEEE 802.3 Clause 40) transmits and receives on all four pairs at once, and so does 10GBASE-T. A Gigabit port therefore needs a four-channel transformer.

It also explains a confusing symptom. A fault on pair 4/5 or 7/8 does not have to kill the link. Many Gigabit PHYs offer a vendor-specific downshift feature: after repeated failed attempts at 1000 Mbps they stop advertising it and link at 100 Mbps on the two good pairs. On the bench that looks like a slow-network bug.

Reading the evidence from firmware

The Clause 22 management registers are the same on every compliant PHY, so you can check the analog side without vendor tools:

/* IEEE 802.3 Clause 22 registers */
#define MII_BMSR       0x01        /* basic mode status */
#define BMSR_LSTATUS   (1u << 2)   /* link status, latches low */
#define BMSR_ANEGDONE  (1u << 5)   /* auto-negotiation complete */
#define MII_STAT1000   0x0A        /* 1000BASE-T status */

uint16_t bmsr = mdio_read(phy, MII_BMSR);  /* returns and clears any latched link-down */
bmsr = mdio_read(phy, MII_BMSR);           /* current state */
bool link_up = bmsr & BMSR_LSTATUS;
bool aneg_ok = bmsr & BMSR_ANEGDONE;
uint16_t stat1000 = mdio_read(phy, MII_STAT1000);

Register 10 also reports local and remote receiver status, whether the link partner can do 1000BASE-T, and an idle error count. A practical reading of the results:

  • Auto-negotiation never completes: compare the termination scheme with the PHY type, then check transformer orientation and pair mapping.
  • The partner reports 1000BASE-T ability but you settle at 100 Mbps: suspect pairs 4/5 and 7/8 (cable, jack or transformer channels) and check whether downshift is enabled.
  • The idle error count keeps climbing at 1000 Mbps: look at layout and magnetics before blaming the driver.
  • The link drops during ESD testing or after a surge: look at protection, not firmware.

Protection and grounding on the schematic

  • Bob Smith termination: on the cable side, each center tap (plus the unused pairs on a 10/100 port) goes through 75 Ω to a shared node, and that node reaches chassis ground via a 1 nF high-voltage capacitor. It handles common-mode termination only; it is not surge protection.
  • TVS diodes on the PHY side clamp whatever transient energy couples through the transformer.
  • A gas discharge tube (GDT) from the cable-side center taps to protective earth diverts surge current.
  • Chassis ground and circuit ground are separate nets. The RJ45 shell goes to chassis ground, and how the two nets meet is a system-level decision.

Three ways to build the port

  • Discrete jack plus separate transformer: the most freedom to place protection parts.
  • RJ45 with integrated magnetics: smaller footprint and shorter traces; the transformer and the Bob Smith network live inside the jack.
  • Transformerless, capacitor-coupled: DC-blocking capacitors and a common-mode choke instead of an isolation transformer. Isolation has to be proven by testing, and it is generally not the choice for a standard 100 m cable run.

Next time a link misbehaves, read BMSR twice and check register 10 before you touch the driver. Those few bits usually tell you which part of this short stretch of circuit to put a probe on.

Sources: IEEE 802.3 Clause 22 (MII management registers) and Clause 40 (1000BASE-T); termination schemes per the PHY vendor's datasheet and reference design.